The choice of the number of turns of the CNC winding machine controller
Choice of winding number counting unit:
The winding count unit can be selected. The number of turns on the display is composed of 5-digit digital tubes. When the default turn count unit is 0.1 turns, the maximum number of turns that can be set by this controller is 9999.9 turns. When the counting unit is changed to 1 circle, the maximum number of circles can reach 99999 circles.
The following other parameters are set in the same way, please refer to:
7.1. Operation mode selection
The factory setting is [10010100].
When entering the operation mode selection state, the step sequence display and the data display display the eight-digit operation mode setting value. If you want to change the setting, please press the fixed value first, and the modification completion button will light up the decimal point. You can press the buttons from right to left to return to the standby state.
number keys to modify its settings
The eight digits represent eight operating mode options, as follows:
1. Cylinder action: 1 is action, 0 is no action.
1 is action; 0 is no action.
2 output mode: Winding shaft operation signal output mode,
0 is CW=forward rotation start, CCW=reverse rotation start; 1 is RUN=running start, F/R=forward and reverse rotation switching.
3 Zero point selection: winding axis zero point and circle count mode selection,
0 means that there is zero point, and it is absolute counting mode; 1 means that there is no zero point, and it is relative counting mode at the same time;
2 means that there is zero point, and it is relative counting mode; 3 means that there is no zero point, and it is absolute counting mode at the same time.
4 Deceleration at both ends: When the position of the spool is close to the width boundary, whether to decelerate the spool,
0 means no deceleration; 1 means to decelerate.
5 Braking mode: When the winding speed is changed from high to low speed, choose whether to make short-term braking,
0 for no braking; 1 for short braking.
6 lap units: When the data display displays the laps, the lap count unit is selected.
0 means 0.1 circle; 1 means 1 circle; 2 means the display unit is 0.05 circle.
7 units of dimension: metric or inch unit selection for cable rod screw,
0 is metric (mm); 1 is imperial (inch).
8 Start modes: Foot (external start) switch operation mode selection,
0: Single start, the foot switch must be ON all the time after starting, if the foot switch is released, the operation will be suspended;
1: It is a double start. After starting, release the foot switch to continue running, and press the foot switch again to suspend operation;
2: Press the start switch to run at a slow speed, release the switch to run at a constant speed;
3: Press the start switch to run at a fixed speed once, and then press it again to run at a slow speed;
4: Press the start switch to execute constant speed operation.